Modular, high-recovery membrane systems engineered specifically to transform challenging coastal raw seawater and high-TDS brackish sources into compliant pharmaceutical process water.
Skid-mounted and weatherized seawater reverse osmosis plants engineered to supply continuous high-purity feedwater for coastal active pharmaceutical ingredient synthesis.
Explore Specifications →Ultra-high pressure membrane technology designed to overcome hydraulic osmotic pressure limits in concentrated pharmaceutical brines and solvent-aqueous waste streams.
Explore Specifications →Rapid deployment, plug-and-play desalination systems coupled with green solar power, ensuring uninterrupted baseline water security for sterile formulation complexes.
Explore Specifications →Double-pass membrane configurations integrating Boron and silica scavenging to safeguard downstream Electrodeionization (EDI) and Multi-Effect Stills.
Explore Specifications →The global pharmaceutical landscape is undergoing a geographic and regulatory transformation. With major Active Pharmaceutical Ingredient (API) chemical synthesis parks and sterile bio-formulation clusters increasingly locating in coastal industrial economic corridors—spanning from the Asia-Pacific coastlines to Gujarat, the Mediterranean basin, and the Gulf Coast—the reliance on depleting municipal or groundwater sources has become a critical operational vulnerability. High-purity process water is not merely a utility in pharmaceutical manufacturing; it is a foundational raw material, critical extraction solvent, and primary cleaning matrix that directly influences finished product efficacy, batch sterility, and regulatory compliance under US FDA (21 CFR Part 211), EMA, and WHO cGMP frameworks.
Desalination Reverse Osmosis (RO), once reserved purely for potable municipal supply, has evolved into an indispensable front-end and core separation technology for coastal pharmaceutical complexes. By deploying multi-barrier Seawater Reverse Osmosis (SWRO), Brackish Water Reverse Osmosis (BWRO), and emerging Osmosis-Assisted Reverse Osmosis (OARO) platforms, modern manufacturers establish absolute water sovereignty. This technical transformation enables continuous production uptime, insulates pharmaceutical operations from municipal water rationing, and provides a stable, low-conductivity feedwater baseline that drastically reduces the operational burden on downstream Purified Water (PW) and Water for Injection (WFI) generation loops.
Over 99.8% nominal rejection of total dissolved solids (TDS), uncharged organic precursors, silica, and polyvalent ions prevents downstream catalyst poisoning in API reaction vessels.
Delivers stable feed conductivity (<10 µS/cm) directly from 35,000–45,000 ppm raw ocean intake, significantly prolonging the lifespan of downstream EDI stacks and polishing resins.
High-recovery membrane concentration reduces hazardous API crystallization mother liquor volumes, facilitating thermal evaporation and solvent-water recovery.
Pharmaceutical process water must rigorously conform to global pharmacopeial monographs, notably the United States Pharmacopeia (USP <1231> "Water for Pharmaceutical Purposes"), European Pharmacopoeia (Ph. Eur.), and Chinese Pharmacopoeia (ChP). While traditional municipal feedwater typically presents a Total Dissolved Solids (TDS) range between 150 and 600 ppm, coastal seawater intake ranges between 32,000 and 45,000 ppm, harboring high concentrations of halides (Chloride, Bromide), Boron, sulfates, heavy metals, marine foulants, and micro-algae metabolites.
Transforming raw hyper-saline seawater into feedwater suitable for API reaction synthesis and Purified Water (PW) loops requires an engineered multistage membrane train designed to eliminate both ionic and microbial bio-contaminants:
| Water Quality Metric | Raw Seawater Intake | Primary SWRO Permeate | Pass-2 Desalination RO Permeate | Final USP/Ph. Eur. PW Standard |
|---|---|---|---|---|
| TDS (ppm / mg/L) | 35,000 – 42,000 | 150 – 350 | < 5 – 15 | < 1.0 (Mineral Residue ≤ 10 ppm) |
| Conductivity (@ 25°C) | 48,000 – 58,000 µS/cm | 250 – 550 µS/cm | < 10 – 20 µS/cm | ≤ 1.3 µS/cm (Stage 1 Online) |
| Boron Concentration | 4.5 – 6.5 mg/L | 0.8 – 1.5 mg/L | < 0.3 mg/L | Trace / Non-detectable |
| Total Organic Carbon (TOC) | 2,000 – 8,000 ppb | < 150 ppb | < 50 ppb | ≤ 500 ppb |
| Microbial Count | > 10,000 CFU/mL | < 10 CFU/100 mL | < 1 CFU/100 mL | ≤ 100 CFU/mL (Alert Limit ≤ 10) |
| Bacterial Endotoxins | High Marine Pyrogens | < 0.5 EU/mL | < 0.05 EU/mL | < 0.25 EU/mL (Ph. Eur. WFI: <0.05) |
In an API or sterile dosage formulation facility, the desalination train must be engineered with pharmaceutical-grade sanitary principles, fail-safe redundancy, and hygienic piping architectures (such as orbital-welded 316L stainless steel or high-grade duplex/super duplex alloys like 2507 and SMO 254 to resist pitting corrosion from high chlorides).
Direct membrane fouling is the principal operational risk in coastal desalination. Marine feedwater undergoes coagulant-dosed Dissolved Air Flotation (DAF) to separate algae blooms and suspended hydrocarbons, followed by pressurized Ultrafiltration (UF) hollow-fiber membrane systems with a nominal molecular weight cut-off (MWCO) of 100–150 kDa. This removes all suspended colloidal matter, reducing the Silt Density Index (SDI15) to < 2.5 and eliminating bacteria, protozoan cysts, and marine microorganisms before high-pressure pumping.
The pre-treated water is pressurized via isobaric positive displacement pumps or high-efficiency multistage centrifugal pumps paired with isobaric Energy Recovery Devices (ERDs), reducing power consumption from 8–10 kWh/m³ down to ≤ 2.8–3.5 kWh/m³. Polyamide thin-film composite (TFC) seawater membranes operate at pressures between 55 and 75 bar. At this stage, over 99.7% of sodium chloride, magnesium, and sulfate salts are rejected into the high-salinity concentrate stream.
Boron presents a significant challenge in API synthesis. At neutral ocean pH (7.8–8.2), Boron exists predominantly as non-ionized boric acid [B(OH)3], which easily slips through standard reverse osmosis membranes due to its small molecular diameter and lack of net charge. In pharmaceutical desalination designs, the first-pass permeate undergoes precise pH adjustment (dosing pharmaceutical-grade NaOH to elevate pH to 9.2–9.8). At this alkaline pH, boric acid dissociates into the negatively charged borate anion [B(OH)4]-, allowing the second-pass Brackish Water RO (BWRO) membranes to achieve >98% Boron rejection, driving permeate Boron levels well below 0.3 ppm.
The double-pass RO permeate provides an ultra-stable, softened, low-TOC feedwater. It directly feeds the Continuous Electrodeionization (CEDI) modules without the rapid scaling or membrane fouling typically triggered by municipal water variations. CEDI polishing continuously strips remaining residual ions via electric field-driven ion exchange, consistently producing process water with resistivity > 10–15 MΩ·cm (Conductivity < 0.1 µS/cm), fully qualified for USP Purified Water and feed to clean steam generators.
Chemical synthesis of active pharmaceutical ingredients involves complex organic multi-step reactions, organometallic catalysts, and aggressive crystallization steps. The introduction of poor-quality process water leads to critical batch failures:
Environmental regulations worldwide are mandating stringent wastewater discharge caps for active ingredient synthesis plants. The toxic, high-salinity effluent from API mother liquor extraction and high-TDS RO concentrate cannot be discharged into coastal ecosystems without severe penalties.
To address this, Osmosis-Assisted Reverse Osmosis (OARO) has emerged as a groundbreaking advancement. Conventional RO is mechanically limited to ~70–80 bar (concentrating brine up to ~70,000–80,000 mg/L TDS) due to membrane mechanical compaction limits. OARO utilizes a specialized permeable support layer that allows a tailored salinity sweep solution on the permeate side, neutralizing hydraulic osmotic pressure differentials. This enables OARO systems to concentrate complex API process wastewater and SWRO brine up to 150,000–220,000 mg/L TDS before feeding small-footprint mechanical vapor recompression (MVR) crystallizers. The result is a true Zero Liquid Discharge (ZLD) ecosystem that recovers >95% of total facility water for reuse.
Furthermore, the integration of containerized, modular SWRO units with rooftop and off-grid solar photovoltaic systems enables pharmaceutical manufacturers to achieve Scope 2 carbon neutralization goals while ensuring uninterrupted operation during coastal grid outages.
Selecting the appropriate water purification architecture depends heavily on feedwater TDS, validation complexity, capital expenditure (CAPEX), and life-cycle operational costs (OPEX):
| Evaluation Parameter | Multi-Effect Distillation (MED/Thermal) | Standard Municipal BWRO + EDI | Integrated Two-Pass SWRO + CEDI | Solar Modular Containerized SWRO |
|---|---|---|---|---|
| Raw Water Versatility | High (Handles High TDS) | Low (Requires Potable Tap Water) | High (Seawater up to 45,000 ppm) | High (Remote/Off-Grid Seawater) |
| Energy Consumption | Very High (>15–25 kWh/m³ heat equiv.) | Low (~1.2–2.0 kWh/m³) | Moderate (~3.0–4.2 kWh/m³) | Net-Zero / Off-Grid Solar Powered |
| Trace Ion & Boron Removal | Moderate (Carryover in steam) | Moderate (Dependent on inlet) | High (pH-Shift Double Pass >99%) | High (Engineered Polishing Pass) |
| Footprint & Skid Modularity | Extremely Large (Vertical Towers) | Compact Indoor Skid | Containerized / Modular Scalable | Plug-and-Play Containerized |
| GMP & 21 CFR Part 11 Validation | Standard Validation | Standard Validation | Fully Automated PLC / SCADA | Integrated IoT / Remote Cloud Telemetry |
According to modern pharmacopeias (USP and Ph. Eur. since 2017), reverse osmosis coupled with appropriate deionization (such as CEDI) and ultrafiltration is legally accepted as a non-thermal production method for Water for Injection (WFI). However, in high-salinity seawater desalination, the SWRO system is most effectively utilized as the heavy-duty pre-treatment stage that feeds an automated double-pass RO/CEDI/UF generation loop or Multi-Effect Water Still, ensuring 100% microbial endotoxin control (<0.05 EU/mL) and total conductivity compliance (≤1.3 µS/cm).
Biofouling control relies on a multi-stage sanitary approach: (1) Pre-treatment via coagulant-assisted Ultrafiltration (UF) to remove organic precursors; (2) Non-oxidizing biocide batch sanitization or upstream UV irradiation (254 nm); (3) Dechlorination via active carbon beds or sodium bisulfite (SBS) with continuous ORP monitoring to protect polyamide membranes; and (4) Routine CIP (Clean-in-Place) and Hot-Water Sanitization (HWS) cycles using certified pharmaceutical-grade cleaning agents.
Boron mimics carbon and nitrogen bonding in certain biological pathways and can act as an unwanted Lewis acid in synthetic organic reactions, contaminating active drug substances or causing catalytic side-reactions. Because boric acid is uncharged at standard pH, two-pass RO systems raise the pH between passes to ~9.5 using NaOH. This converts boric acid into negatively charged borate ions, enabling the second-pass membrane to reject over 98% of residual Boron.
Due to extreme chloride concentrations in raw seawater (typically >19,000 mg/L Cl-), all high-pressure wetted metallic surfaces before membrane desalination utilize Super Duplex Stainless Steel (UNS S32750 / 2507) or 6-Moly Austenitic alloys (SMO 254). Post-membrane permeate lines, which transport low-conductivity pure water, utilize sanitary 316L Stainless Steel with electropolished internal surfaces (Ra < 0.4–0.6 µm) or PVDF piping with orbital sanitary clamping.
Containerized seawater desalination plants are fully pre-engineered, piped, wired, and tested in a controlled factory environment prior to shipment. This modular plug-and-play format eliminates months of on-site civil and mechanical construction at coastal API sites, offers integrated environmental control (HVAC), provides automated PLC/SCADA data acquisition compliant with 21 CFR Part 11, and allows rapid capacity scaling as drug production quotas expand.
Shanghai Tongjie Environmental Technology Co., Ltd., founded in 2010, is recognized as a National High-Tech Enterprise and a Shanghai Specialized & Sophisticated Enterprise. The company specializes in membrane-based applications, integrating R&D, design, manufacturing, engineering, and operation services. Holding Class II contracting qualifications in environmental protection engineering as well as mechanical and electrical installation, the company focuses its business on fields such as seawater desalination, industrial pure water, water reuse, high-salinity wastewater and zero liquid discharge (ZLD), and oilfield produced water. The company holds multiple invention and utility patents, software copyrights, and has obtained ISO certifications.
Years Industry Experience
Patents Held
R&D Team Specialists
Cooperative Agencies
Fully certified quality management and safety standards ensuring rigorous compliance for international pharmaceutical and industrial projects.
Latest updates on international exhibitions, cutting-edge water solutions, and mega-scale industrial desalination engineering.
From June 16 to 18, 2026, the 21st China Pharmaceutical Raw Materials Exhibition (CPHI China) and PMEC China showcased Tongjie's high-purity water solutions for API manufacturing.
Read Full Story →
As the mainstream process in the current desalination market, membrane-based seawater desalination technology provides rapid, low-cost pure water security across diverse global scenarios.
Read Full Story →
Sinosteel & Tongjie Environmental partner on a landmark large-scale seawater desalination facility in Algeria, driving energy recovery and industrial water sustainability.
Read Full Story →Explore our complete range of high-efficiency seawater desalination plants, osmosis-assisted systems, and modular containerized clean water units.
Complete turnkey containerized desalination systems engineered for high-salinity coastal water conversion with automated CIP cycles.
View Details →Proprietary osmotic membrane units designed to achieve extreme concentration in high-TDS pharmaceutical waste brines.
View Details →Rapid-deployment plug-and-play desalination packages integrated with solar power for zero-carbon pharma utility operation.
View Details →Equipped with caustic dosing and secondary low-energy brackish membranes to achieve Boron concentrations <0.3 ppm.
View Details →Specialized separation skids tailored for recovering active compounds and reducing hazardous thermal evaporator feed volumes.
View Details →Hollow-fiber ultrafiltration integrated with high-pressure seawater reverse osmosis for high-silt coastal marine waters.
View Details →Engineered for large-scale bulk pharmaceutical chemical manufacturing parks requiring multi-thousand m³/day capacity.
View Details →Fully compliant with 21 CFR Part 11 digital record requirements, featuring remote telemetry, predictive CIP, and continuous TOC tracking.
View Details →Thank you for your interest in TONGJIE! Contact us today to receive a free engineering consultation, process flow design, and tailored quote for your pharmaceutical water treatment requirements.
Talk About Your Needs