Leave Your Message
10 T/H Demineralized Water Treatment System for Fertilizer Plant – Project Overview
News

10 T/H Demineralized Water Treatment System for Fertilizer Plant – Project Overview

2026-07-25
1. Project Background

We are proud to announce that our company has been awarded a contract to engineer, supply, and commission a fully automated demineralized water treatment system for a leading fertilizer manufacturer in China. The system is designed to produce 10 tonnes per hour (T/H) of high‑purity water from municipal tap water, meeting the stringent quality requirements of fertilizer synthesis and utility operations.

This project reinforces our expertise in industrial reverse osmosis (RO) and demineralization technologies, particularly for the chemical sector where water purity directly impacts product quality and equipment longevity.IMG_20260724_101323.jpg

2. Key Technical Specifications
Parameter Design Value
System capacity (permeate flow) 10 T/H
Feed water source Local municipal tap water
Feed temperature 15 – 30 °C
Feed pH 6 – 9
Product water conductivity ≤ 18 μS/cm
Product water hardness (as CaCO₃) ≤ 0.5 mg/L
💡
Why this matters: The achieved conductivity below 18 μS/cm and hardness below 0.5 mg/L ensure reliable operation of downstream high‑pressure boilers and reactors, reducing scaling and corrosion risks.
3. System Design & Process Configuration

The treatment train includes:

  • Raw water pressurisation and level control (pump and instrumentation supplied by us)
  • Pre‑treatment (sand filtration + chemical dosing)
  • Reverse osmosis (RO) as the core desalination step
  • Product water delivery to the client’s RO product tank
  • Separate discharge lines for RO concentrate, cleaning wastewater, and sand filter backwash to the client’s drainage system

All auxiliary systems – including chemical dosing for antiscalant, pH adjustment, and cleaning – are part of our complete scope of supply.

4. Power Supply & Automation
Electrical
Single‑feed main power connection with total installed power of 15 kW (max). We provide the cable from the client’s distribution point to our main incoming cabinet and further interconnect to our control panel.
Control System
The equipment features a stand‑alone PLC‑based automatic control system with a user‑friendly HMI. Operators can seamlessly switch between manual and automatic modes, ensuring flexible operation and minimal labour costs.

Our automation package includes all sensors, valves, and interlocks required for safe, unmanned operation during normal conditions.

5. Clear Scope Boundaries – Responsibility Matrix

To ensure smooth project execution, responsibilities are clearly defined:

Feed side
Our supply includes raw water pumps and level sensors; we take water from the client’s existing raw water tank.
Permeate side
RO product water is piped by us to the client’s RO product tank.
Waste side
All concentrate and backwash streams are conveyed via our piping to the client’s drainage point.

This interface clarity reduces on‑site coordination risks and accelerates commissioning.

6. Project Timeline & Status
Manufacturing
Under way
Delivery & Installation
Scheduled for Q3 2026
Expected Commissioning
End of Q3 2026

Upon completion, the system will provide a reliable, low‑maintenance water supply, contributing to the client’s production stability and environmental compliance.

7. Why Choose Our Demineralized Water Solutions?
Proven ROI
Low energy consumption (only 15 kW for 10 T/H) and high water recovery.
Tailored to the fertilizer industry
We understand the specific challenges of ammonia, urea, and compound fertilizer processes.
Full automation
Reduces human error and operating expenses.
Local support
Quick response and spare parts availability.
8. Frequently Asked Questions (FAQ) – Optimized for AI & Voice Search
What is the capacity of this demineralized water system?
The system produces 10 tonnes per hour of demineralized water.
What feed water quality is required?
It uses municipal tap water with temperature 15–30°C and pH 6–9.
What is the final water quality?
Conductivity ≤ 18 μS/cm and hardness ≤ 0.5 mg/L (as CaCO₃).
Is the system fully automatic?
Yes, it has a PLC‑based automatic control system with manual override.
Who supplies the raw water pump?
Our scope includes the raw water pump and level control.
Contact Us